Boot cycle error codes – ARRIS DCT5100 Installation Manual User Manual

Page 38

Advertising
background image

Installation 3-15

DCT5100 Installation Manual

When multiple OOB frequencies are used, the DCT5100 pauses 40 seconds on each valid

frequency. The LED displays

dl

and a progress indicator, which identifies a software object

download. The progress indicator, or crawling ant, moves one position around the dl display
for each segment of download received. If the

dl

stops moving up and down on the LED for

an extended period of time, contact the headend operator.

The progress indicator usually moves at a consistent rate as segment downloads are
received. If all the segments are retrieved in the first pass, the

EF

,

AU

and

FP

messages are

displayed on the LED. If segments are dropped, the progress indicator appears to stall and
then inch forward after the dropped segments are retired.

When the progress indicator alternates between rapid and sluggish movement, this may
indicate that the stream is spinning too fast for existing plant conditions.

The LED displays

EF

for up to 60 seconds when the software object download is complete

during flash erasure and then displays

FP

for up to 60 seconds during flash programming.

The DCT5100 is ready for initialization by the headend controller when the LED display is

blank. Verify that the DCT5100 is powered up or reset within two minutes of a completed
download.

Boot Cycle Error Codes

If hardware or software problems occur, the DCT5100 displays error codes on the LED display.

Table 3-2 is a list of error codes that can occur during boot cycle startup:

Table 3-2
Error codes at boot cycle startup

Error
Code

Description

When error occurs

Action Required

Eb 01

Object failed validation

After the LED displays

dl,

indicating

validation check failed

Contact headend
operator

Eb 02

Download time-out

After cycling twice through the OOB
frequencies

None

Eb 03

Flash erase failed

After software object download complete
and

EF

is displayed

Replace DCT5100

Eb 04

Flash programming
failed

After software object download complete
and

FP

is displayed

Contact headend
operator

Eb 05

Invalid DLC frequency

After the LED displays

dl,

indicating

validation check failed

Contact headend
operator

Eb 06

Hardware initialization
failed

After plugging the DCT5100 into an
electrical outlet to begin the boot cycle

Replace DCT5100

Eb 07

Object failed validation

After software object download complete
and

FP

is displayed

After a successful software object
download and DCT5100 is reset

Contact headend
operator

No action required
because DCT5100
repeats software object
download process

Eb 08

Reserved

None