7.3 AA Relay Channel (AA) (Output 4 FM Relay)

This is a changeover relay. Connections are made to terminals AA, AB, and AC. OP4 beacon is operated from the AA
relay output channel. Output AA (4) has the same functionality as OP-1 and OP-3 – the parameters are repeated here
for clarity.

FM Relay

OUTPUT AA LIST ‘a a ’

Name

Scrolling

Display

Parameter

Description

Value

Defaul

t

Access

Level

4 . T Y P E

OUTPUT 4
TYPE

Displays the type of
output

reLy Relay output

reLy Read only

4.FUNC

OUTPUT 4
FUNCTION

The function may be
turned off, otherwise
set to

d.out

none

Disabled. If disabled no further
parameters are shown

Conf

d.out Digital output

4.SRC.A

OUTPUT 4
SOURCE A

Selects the source of
an event which will
operate the output
relay

The output status is
the result of an OR of
Src A, Src B, Src C,
and Src D

Up to four events can,
therefore, operate the
output
See section 7.1.2.

none No event connected to the

output

none Conf

4.SRC.B

OUTPUT 4
SOURCE B

1.--- Alarm 1

The --- indicates the
alarm type. If the
alarm is not
configured
AL.(Alarm no) is
shown

2.--- Alarm 2

4.SRC.C

OUTPUT 4
SOURCE C

3.--- Alarm 3
4.--- Alarm4

4.SRC.D

OUTPUT 4
SOURCE D

ALL.A All alarms
nw.AL Any new alarm
sbr

Sensor break alarm

Pwr.f Power fail
O.rng Output relay operates if the

indicator input is over range

4.SENS

OUTPUT 4
SENSE

To configure the
sense of the output
channel.
See also section 7.2.1

nor
Inv

Normal
Inverted