Series 3L Indicators

45




46 – Timer Run/Reset
47 – Timer Hold
48 – Auto/Manual Select
49 – Standby Select




L.SENS

Configures the polarity of the logic
input channel A (0 = Normal, 1 =
Inverted)

12361

L.TYPE
(LB)

Logic Input B channel hardware
type
0 – None
1 – Logic Inputs

12362

L.D.IN
(LB)









Logic input B function)
40 – None
41 – Acknowledge all alarms
42 – Select SP1/2
43 – Lock All Keys
44 – Timer Reset
45 – Timer Run
46 – Timer Run/Reset
47 – Timer Hold
48 – Auto/Manual Select
49 – Standby Select

12363









L.SENS
(LB)

Configures the polarity of the logic
input channel B (0 = Normal, 1 =
Inverted)

12377

ID


Comms Module Type
0 – None
1 – RS485
2 – RS232

12544

BAUD




Baud Rate
0 – 9600
1 – 19200
2 – 4800
3 – 2400
4 – 1200

12548




PRTY


Parity setting
0 – None
1 – Even
2 – Odd

12549


DELAY

RX/TX Delay – (0 = no delay, 1 =
delay) Select if a delay is required
between received and transmitted
comms messages. Sometimes
required when intelligent RS485
adaptors are used.

12550

RETRN

Comms Retransmission Variable
selection:
0 – Off
1 – Working Setpoint
2 – PV
3 – Output Power
4 – Error

12551

REG.AD

Modbus register address to
broadcast retransmission to. For
example if you wish to retransmit
the working setpoint from one
Series 3L to a group of slaves, and
receive the master working setpoint
into the slaves’ remote setpoint, set
this variable to 26 (the address of
the remote setpoint in the slave
units).

12552

Cal 3 offset

12558

Cal 4 offset

12559

1.ID


IO channel 1 hardware type
0 – None
1 – Relay

12672


1.FUNC

I/O Channel Function
0 – None (or Telemetry Output)

12674




1 – Digital Output

1.SRC.A

IO Channel 1 Source A
0 – None
1 – Alarm 1
2 – Alarm 2
3 – Alarm 3
4 – Alarm 4
5 – All Alarms (1-4)
6 – New Alarm
9 – Sensor Break Alarm

12677

1.SRC.B

IO Channel 1 Source B
As IO Channel 1 Source A (Modbus
address 12678)

12678

1.SRC.C

IO Channel 1 Source C
As IO Channel 1 Source A (Modbus
address 12678)

12679

1.SRC.D

IO Channel 1 Source D
As IO Channel 1 Source A (Modbus
address 12678)

12680

1.SENS

Configures the polarity of the input
or output channel (0 = Normal, 1 =
Inverted)

12681

IO1 high

12682

IO1 telemetry

12683

3.ID

Output 3 Type
0 – None
1 – Relay

12800

3.FUNC

Output 3 Channel function
0 – None (or Telemetry Output)
1 – Digital Output

12803

3.SRC.A

Output 3 source A
As IO Channel 1 Source A (Modbus
address 12678)

12806

3.SRC.B

Output 3 source B
As IO Channel 1 Source A (Modbus
address 12678)

12807

3.SRC.C

Output 3 source C
As IO Channel 1 Source A (Modbus
address 12678)

12808

3.SRC.D

Output 3 source D
As IO Channel 1 Source A (Modbus
address 12678)

12809

3.SENS

Output 3 Polarity (0 = Normal, 1 =
Inverted)

12810

Output 3 telemetry

12812

4.TYPE

Output AA Type
0 – None
1 – Relay

13056

4.FUNC

Output 4 Channel function
0 – None (or Telemetry Output)
1 – Digital Output

13059

4.SRC.A

Output AA source A
As IO Channel 1 Source A (Modbus
address 12678)

13062

4.SRC.B

Output AA source B
As IO Channel 1 Source A (Modbus
address 12678)

13063

4.SRC.C

Output AA source C
As IO Channel 1 Source A (Modbus
address 12678)

13064

4.SRC.D

Output AA source D
As IO Channel 1 Source A (Modbus
address 12678)

13065

4.SENS

Output AA sense (0 = Normal, 1 =
Inverted)

13066