Source[<n>]]:frequency:couple:mode – RIGOL DG1000Z Series User Manual

Page 104

Advertising
background image

RIGOL

Chapter 2 Command System

2-92

DG1000Z Programming Guide

[:SOURce[<n>]]:FREQuency:COUPle:MODE

Syntax

[:SOURce[<n>]]:FREQuency:COUPle:MODE {OFFSet|RATio}

[:SOURce[<n>]]:FREQuency:COUPle:MODE?

Description

Set the frequency coupling mode to frequency deviation (OFFSet) or frequency ratio

(RATio).
Query the frequency coupling mode.

Parameter

Name

Type

Range

Default

[<n>]

Discrete

1|2

1

{OFFSet|RATio}

Discrete

OFFSet|RATio

RATio

Explanation

 Frequency deviation mode: the frequencies of CH1 and CH2 fulfills certain

deviation relation: F

CH2

=F

CH1

+F

Dev

(the reference source is CH1); F

CH1

=F

CH2

-F

Dev

(the reference source is CH2). Wherein, F

CH1

is the frequency of CH1, F

CH2

is the

frequency of CH2 and F

Dev

is the specified frequency deviation.

 Frequency ratio mode: the frequencies of CH1 and CH2 fulfills certain ratio

relation: F

CH2

=F

CH1

*F

Ratio

(the reference source is CH1); F

CH1

=F

CH2

/F

Ratio

(the

reference source is CH2). Wherein, F

CH1

is the frequency of CH1, F

CH2

is the

frequency of CH2 and F

Ratio

is the specified frequency ratio.

 After the frequency coupling, the instrument will adjust the frequency upper

limit or lower limit of the other channel to avoid parameter overrange when the

frequency of any of CH1 and CH2 exceeds the frequency upper limit or lower

limit of the channel.

 Please select the desired frequency coupling mode and set the corresponding

frequency deviation (

[:SOURce[<n>]]:FREQuency:COUPle:OFFSet

) or

frequency ration (

[:SOURce[<n>]]:FREQuency:COUPle:RATio

) before enabling

the frequency coupling function

(

[:SOURce[<n>]]:FREQuency:COUPle[:STATe]

). You cannot set the frequency

coupling mode and the frequency deviation/ratio after the frequency coupling

function is enabled.

 You can also send the

:COUPling:FREQuency:MODE

command to set and query

the frequency coupling mode.

Return Format

The query returns OFFSET or RATIO.

Example

:FREQ:COUP:MODE OFFS /*Set the frequency coupling mode to frequency

deviation*/

:FREQ:COUP:MODE? /*Query the frequency coupling mode and the query

returns OFFSET*/

Related

Commands

:COUPling:FREQuency:MODE

[:SOURce[<n>]]:FREQuency:COUPle:OFFSet

[:SOURce[<n>]]:FREQuency:COUPle:RATio
[:SOURce[<n>]]:FREQuency:COUPle[:STATe]

Advertising