Source[:mod]:pm commands, Source[<n>]][:mod]:pm[:deviation, Source[:mod]:pm commands -136 – RIGOL DG1000Z Series User Manual

Page 148

Advertising
background image

RIGOL

Chapter 2 Command System

2-136

DG1000Z Programming Guide

:SOURce[:MOD]:PM Commands

[:SOURce[<n>]][:MOD]:PM[:DEViation]

Syntax

[:SOURce[<n>]][:MOD]:PM[:DEViation] {<deviation>|MINimum|MAXimum}

[:SOURce[<n>]][:MOD]:PM[:DEViation]? [MINimum|MAXimum]

Description

Set the PM phase deviation of the specified channel.
Query the PM phase deviation of the specified channel.

Parameter

Name

Type

Range

Default

[<n>]

Discrete

1|2

1

<deviation>

Real

0° to 360°

90°

Explanation

 When [:SOURce[<n>]] or [<n>] is omitted, the system sets the related

parameters of CH1 by default.

 Phase deviation is the deviation of the modulating waveform phase relative to the

carrier waveform phase.

 When external modulation source is selected

(

[:SOURce[<n>]][:MOD]:PM:SOURce

), the phase deviation is controlled by the

±5V signal level from the corresponding [Mod/Trig/FSK/Sync] connector at

the rear panel. For example, if the phase deviation is set to 180°, +5V signal level

corresponds to a 180º phase variation. The lower the external signal level, the

less deviation would be generated.

Return Format

The query returns the PM phase deviation in scientific notation with 7 effective digits,

for example, 5.000000E+01 (the PM phase deviation is 50°).

Example

:SOUR1:PM 50 /*Set the PM phase deviation of CH1 to 50°*/
:SOUR1:PM? /*Query the PM phase deviation of CH1 and the query returns

5.000000E+01*/

Related

Command

[:SOURce[<n>]][:MOD]:PM:SOURce

Advertising