:COUPling:AMPL:RATio

Syntax

:COUPling:AMPL:RATio {<value>|MINimum|MAXimum}

:COUPling:AMPL:RATio?

Description

Set the amplitude ratio in the amplitude coupling.
Query the amplitude ratio in the amplitude coupling.

Parameter

Name

Type

Range

Default

<value>

Real

0.001 to 1000

1

Explanation

 Select the desired amplitude coupling mode (

:COUPling:AMPL:MODE

) and set

the corresponding amplitude deviation (

:COUPling:AMPL:DEViation

) or

amplitude ratio before enabling the amplitude coupling function

(

:COUPling:AMPL[:STATe]

). You cannot set the amplitude coupling mode and

amplitude deviation/ratio after the amplitude coupling function is enabled.

 When the amplitude coupling function is disabled, if the current amplitude

coupling mode is amplitude ratio, send this command can set the amplitude

ratio; if the current amplitude coupling mode is amplitude deviation, send this

command can set the amplitude coupling mode to amplitude ratio and set the

amplitude ratio.

Return Format

The query returns the amplitude ratio in scientific notation. The return value contains

7 effective digits, for example, 1.123000E+00 (the amplitude ratio is 1.123).

Example

:COUP:AMPL:RAT 1.123 /*Set the amplitude ratio in the amplitude coupling to

1.123*/

:COUP:AMPL:RAT? /*Query the amplitude ratio in the amplitude coupling

and the query returns 1.123000E+00*/