Control using the tally/gpio connector, Specification of the tally/gpio connector, Inputting a control signal – Roland VR-6HD Direct Streaming AV Mixer User Manual

Page 90: Inputting a control signal” (p. 90), Other functions, Pin layout, Tally output, Control input, Pin assignments

Advertising
background image

90

Other Functions

Control Using the TALLY/GPIO Connector

You can use control signals inputted to the TALLY/GPIO connector via GPI to remotely control the VR-6HD from an external device.
Also, you can output tally signals or GPO control signals from the TALLY/GPIO connector.

Specification of the TALLY/GPIO Connector

Pin layout

5 4 3 2 1

15

16

17

18

19

20

21

22

23

24

25

14

10

11

12

13

9 8 7 6

DB-25 type (female)

Tally output

Trigger

method

Open collector

Maximum

input

12 V/120 mA

Control input

Trigger

method

No-voltage contact (make-

contact) triggering

Contact

capacity

DC 24 V 0.1 A or higher

Input method

Photocoupler

Pin assignments

Pin no.

Pin name

Function (default value)

1

TALLY/GPO 1

PGM VIDEO IN 1

2

TALLY/GPO 2

PST VIDEO IN 1

3

TALLY/GPO 3

PGM VIDEO IN 2

4

TALLY/GPO 4

PST VIDEO IN 2

5

TALLY/GPO 5

PGM VIDEO IN 3

6

TALLY/GPO 6

PST VIDEO IN 3

7

TALLY/GPO 7

PGM VIDEO IN 4

8

TALLY/GPO 8

PST VIDEO IN 4

9

TALLY/GPO 9

PGM VIDEO IN 5

10

TALLY/GPO 10

PST VIDEO IN 5

11

TALLY/GPO 11

PGM VIDEO IN 6

12

TALLY/GPO 12

PST VIDEO IN 6

13

TALLY/GPO 13

GPO 1

14

TALLY/GPO 14

GPO 2

15

TALLY/GPO 15

GPO 3

16

TALLY/GPO 16

GPO 4

17

GND

18

GPI 1

Not assigned

19

GPI 2

Not assigned

20

GPI 3

Not assigned

21

GPI 4

Not assigned

22

GPI 5

Not assigned

23

GPI 6

Not assigned

24

GPI 7

Not assigned

25

GPI 8

Not assigned

Inputting a Control Signal

When an external control signal is input, the functions assigned to GPI

1–8 are executed.

1 .

From the [MENU] button

Ó

“REMOTE”

Ó

“GPI”

Ó

select GPI

1–8 “CATEGORY” or ”VALUE”, and press the [VALUE] knob.

2 .

Use the [VALUE] knob to select the functions assigned to GPI

1–8, and then press [VALUE].

Á

CATEGORY

Value

Explanation

N/A

No function is assigned.

PGM CH SELECT

Switches the video sent to the PGM bus.

PST CH SELECT

Switches the video sent to the PST bus.

AUX CH SELECT

Switches the video sent to the AUX bus.

INPUT 1–6 ASSIGN

Changes the video assigned to INPUT 1–6.

STILL OUTPUT

Pauses the normal output, and previews or

final outputs a cut of the still image.

VIDEO PLAYER

OUTPUT

Temporarily pauses the normal output, and

previews or final outputs a cut of the video

player’s video signal.

PinP & KEY 1–2 SOURCE

Switches the video source of the inset screen.

DSK SOURCE

Switches the DSK video source.

BUTTON CONTROL

This works the same as when you press the

button selected in “VALUE”.

AUDIO INPUT MUTE

Turns the mute function on/off for the input audio.

AUDIO OUTPUT MUTE

Turns the mute function on/off for the

output audio.

AUDIO INPUT SOLO

Turns the solo function on/off for the input

audio.

AUDIO OUTPUT SOLO

Turns the solo function on/off for the output audio.

VOICE CHANGER

Turns the voice changer function on/off.

AUTO MIXING

Turns the auto mixing function on/off.

REVERB(MOMENTARY)

Reverb turns on only while a control signal

is input.

REVERB(ALTERNATE)

Turns reverb on/off.

OUTPUT FADE

The final output video fades in/out.

LOAD MEMORY

Recalls a scene memory.

INPUT SCAN

Each time a control signal is input, the INPUT

1–6 video changes in order.

SCENE MEMORY SCAN

Each time a control signal is input scene

memories 1–32 are recalled in order.

PinP & KEY 1–2 SCAN

Each time a control signal is input, the PinP &

KEY 1–2 inset screen videos switch in order.

DSK SCAN

Each time a control signal is input, the DSK

caption video changes in order.

MACRO EXECUTE

Executes a macro (a series of recorded

operations).

SEQUENCER

When the sequencer function is on, this

works the same as when you press the

button selected in “VALUE”.

GPO (ONE SHOT)

Outputs a control signal for 0.5 seconds.

GPO (ALTERNATE)

The control signal output is switched on/off

each time a control signal is input.

Á

VALUE

Configures the detailed settings related to “CATEGORY”.

Advertising