Specifications, Technical and operating specifications, Table 1 specifications - general – Honeywell HERCULINE 2000 User Manual

Page 13

Advertising
background image

Specifications

Technical and Operating Specifications

Revision 7

HercuLine™ 2000 Series Actuator - Installation, Operation and Maintenance Manual

5

7/08

Specifications

This section provides you with the technical specifications and the model selection guide for the
HercuLine

®

2000 Series Actuators.

Technical and Operating Specifications

Table 1 Specifications - General

Physical

Weight

2000: 25 lb. (11.36 kg)
2001,2002: 27 lbs. (12.27 kg)

Enclosure

Precision-machined die cast aluminum housing, finished in light gray powder coat
epoxy.

Gear Train

Alloy steel, high efficiency steel spur gear primary train. Precision ground, self-
locking/self releasing worm gear final mesh.

Mechanical Stops

Factory set at 90° or 150° (+/-5°).

Attention: Do not adjust the mechanical Stops. Adjusting the stops will void
the warranty

Storage Temperature

–40 °C to +93 °C (–40 °C to +200 °F)

Relative Humidity

0 % to 99 % R.H. non-condensing over the full operating temperature range.

Scale

0 % to 100 % corresponding to full crank arm travel.

Crank Arm

Adjustable radii 1.0 in (25.4mm) to a maximum of 2.8 in (71.1mm). Position
adjustable through 360° rotation.

Output Shaft

0.625+/-.005 in (15.88 +/-.13mm) diameter

Rotation

90° or 150° degrees between 0 % and 100 % on scale, limited by mechanical stops.

Manual Handwheel

Provides a means of positioning the actuator in the event of a power failure or set-
up.

Lubrication

Texaco Starplex 2 EP Grease

Output Torque/Full
Travel Stroking Time

Torque lb-in (N
M)

50 / (6.0)
100 / (11.5)
200 / (22.5)
400 / (45.0)
400 / (45.0)

50 Hz (90

°/150°)

4.5 / 7.5

9 / 15

18 / 30

36 / 60

54 / 90

60 Hz (90

°/150°)

4 / 6
7 / 12
15 / 25
30 / 50
45 / 75

Advertising