Specifications

Model Selection Guide

Revision 7

HercuLine™ 2000 Series Actuator - Installation, Operation and Maintenance Manual

11

7/08

2002 2003

TABLE VI - OPTIONS

Selection

Local keypad/

No local display interface supplied

(Note 2)

0_ _ _ _ _

display

Integrally mounted local display/keypad interface

1_ _ _ _ _

Local Auto/

No auto/manual switch

_ 0_ _ _ _

manual switch

Auto/manual switch with "Out of Auto Contact"

_ 1_ _ _ _

Auto/manual switch with "Out of Auto Contact"

_ 2_ _ _ _

Handwheel

No Handwheel

_ _ 0_ _ _

Handwheel

_ _ 1_ _ _

Certificates

None

_ _ _ 0 _ _

Certificate of Conformance

_ _ _ 1_ _

Approvals

UL Type 4/IP66, CSA

(Note 4)

_ _ _ _ 0_

CE

_ _ _ _ 1_

Shipped Rotation

Counter clockwise shaft rotation on increasing signal

_ _ _ _ _0

Clockwise shaft rotation on increasing signal

_ _ _ _ _1

TABLE VII - COMMUNICATIONS/PROTOCOL
None

No communications option board or protocol

0

Modbus RTU RS485 RS-485 Modbus compliant - standard with EEU

1

HART 5

HART Communications Protocol

2

TABLE VIII - MANUALS
Standard

English

0

TABLE IX - FACTORY OPTIONS
Factory Options

None

Restrictions

a

IV

_ 00

IV

_ 60, _ 80

II

II

II

II

ACCESSORIES
Mounting Hardware

Mounting plate adapter for Barber Colman Series MP495
Mounting plate adapter for Landis & Staefa SQM53/56
Direct Couple Valve Hardware
North American Valve Retrofit Kit

Linkage Assembly

Ball joint for 5/16" dia. Pushrod
Pushrod 12 in. (304,5 mm) long, 5/16 " dia.
Pushrod 18 in. (457,2 mm) long, 5/16 " dia.
Pushrod 24 in. 609,6 mm) long, 5/16 " dia.
Pushrod 48 in. (1219,2 mm) long, 5/16 " dia.

HART

Turk Cable for Handheld Connection

51452352-501

Handheld Config.

HercuLink

TM

Palm Software

(Note 3)

Battery powered 232/485 converter with cable

Remote Mount

Remote 4-20 mA requires 135 ohm fdbk, 120V 50/60Hz

Control

Remote 4-20 mA requires 1000 ohm fdbk, 120V 50/60Hz
Remote 4-20 mA requires 135 ohm fdbk, 220V 50/60Hz
Remote 135 ohm input requires 135 ohm fdbk, 120V 50/60Hz

Notes:

1. 135 ohm available by parallelling 1K potentiometer with 158 Ohm resistor (supplied).
2. HercuLink

TM

software (pn 51452354-509), RS232/485 converter (pn 51452354-510),

customer supplied Palm

TM

PDA running OS3.5 or higher and Palm serial cable are required

for the 2001 and 2002 actuators if no display is selected.
3. Requires PDA manufacturer's serial interface cable.
4. CSA approval is good for 75°C and a maximum relay load of 3.5 amps or 70°C with a

relay load of 5 amps.

00

51452354-506
51452354-507

51452354-503
51452354-511
51452354-504
51452354-505

51452354-501
51452354-502

2000 2001

Available Only With

Table

Selection

Not Available With

150

090

R7195A1056

R7195B1021

R7195A1064

51452354-508

R7195A1031

51452354-510

51452354-509

Restriction

Letter

c

150

090

b

Table

Selection