Section 6

Electrical System

Part No. 80-1214-3

6-47

Component Specifications and Diagnostics

ICE/OFF/CLEAN TOGGLE SWITCH

Function

The switch is used to place the ice machine in ICE, OFF
or CLEAN mode of operation.

Specifications

Single-pole, single-throw switch. The switch is
connected into a varying low D.C. voltage circuit.

Check Procedure

NOTE: Because of a wide variation in D.C. voltage, it is
not recommended that voltage is used to check toggle
switch operation.

1. Inspect the toggle switch for correct wiring.

2. Isolate the toggle switch by disconnecting all wires

from the switch, or by disconnecting the Molex
connector from the control board.

3. Check across the toggle switch terminals using a

calibrated ohm meter. Note where the wire numbers
are connected to the switch terminals, or refer to the
wiring diagram to take proper readings.

4. Replace the toggle switch if ohm readings do not

match all three switch settings.

BIN LEVEL PROBE

Function

The bin level probe shuts off the ice machine after the
bin fills with ice.

To start ice making, the bin level probe must be open
(Bin Level light off). If the probe is closed (Bin Level light
on) when the toggle switch is moved to ICE, the control
system waits until the bin level probe opens (Bin Level
light off) before starting an ice making sequence. If the
bin level probe is disconnected from the circuit board,
the ice machine will not start. This prevents overfilling
the bin with ice.

FAILURE MODES

Bin Level Probe Open or Disconnected

The ice machine will not start and continuously flashes
the Bin Level light. Opening the bin level probe for
15 continuous seconds in the Freeze cycle will initiate an
Automatic Shut-Off sequence.

Bin Level Probe Closed or Shorted

The ice machine will not start and the Bin Level light is
energized.

Shorting the probe for 30 continuous seconds in the
Freeze cycle will initiate an Automatic Shut-Off
sequence.

CHECK PROCEDURE

Bin Level Probe Open or Disconnected

The ice machine will not start and continuously flashes
the Bin Level light.

1. Move toggle switch from OFF to ICE to OFF to ICE

to verify ice machine is not in an 8-minute lockout.

Switch Setting

Terminals

Ohm Reading

ICE

19-20

Closed

19-23

Open

20-23

Open

CLEAN

19-20

Open

19-23

Closed

20-23

Open

OFF

19-20

Open

19-23

Open

20-23

Open

Control Board

Bin Level Light

Cause

Off

Ice machine was in an

Automatic Shut-Off mode

(8-minute lockout).

Flashes

Go to step 2.

Revised 8/2003