Electrical System

Section 6

6-48

Part No. 80-1214-3

2. Disconnect bin level probe from control board and

check continuity (ohms) from the female connector
to the bin level probe.

3. Remove bin level probe from ice chute and clean

with Manitowoc Ice Machine Cleaner and Sanitizer.
Rinse well with fresh water, reinstall and monitor the
Bin light.

4. Disconnect bin level probe wire from the control

board and place a jumper from the bin level terminal
to ground.

Bin Level Probe Closed or Shorted

The ice machine will not start and the Bin Level light is
energized continuously.

1. Verify ice is not in contact with bin level probe.

2. Disconnect bin level probe wire from the control

board.

Continuity

Cause

No

Replace bin level probe.

Yes

Go to step 3.

Control Board

Bin Level Light

Cause

Off

Bin level probe

needed cleaning.

Flashes

Go to step 4.

CHECK FOR CONTINUITY

CONNECTOR TO GROUND.

Control Board

Bin Level Light

Cause

On

Replace bin level probe.

Flashes

Reconfirm control board is not

in an 8-minute lockout. Repeat

steps 1 – 4, then replace

control board.

Control Board

Bin Level Light

Cause

Off

Clean bin level probe.

On

Replace control board.

DISCONNECT BIN LEVEL PROBE

FROM CONTROL BOARD.

Revised 8/2003