Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 70

Advertising
background image

Electrical System

Section 6

6-8

Part No. 80-1214-3

Automatic Shut-Off

3B. DRAIN EVAPORATOR

To allow water to drain from the
evaporator, the dump valve energizes
for 45 seconds, then de-energizes.

SV3038

RELAY

K1

GROUND

L1

L2 (N)

(21)

(65)

CONTACTOR

COIL

(90)

HIGH

PRESSURE

CUT-OUT

(95)

RELAY

K2

RELAY

K3

RELAY K4

(25)

10 AMP

FUSE

(46)

GEARMOTOR

(47)

GEARMOTOR

RUN CAPACITOR

(48)

(43)

(56)

WATER FLOAT

VALVE COIL

(52)

(22)

(55)

(51)

DUMP VALVE

COIL

FAN MOTOR

(AIR-COOLED ONLY)

(10)

(11)

(14)

(41)

CONTACTOR

CONTACTS

L1

T1

RUN

START

(44)

3B. Drain Evaporator (45 Seconds)

Toggle Switch

ICE

Bin Level Probe

Closed (Ice Contacting Probe)

Control Board Relays

#1

Contactor Coil

Open / OFF

Compressor

OFF

Condenser Fan Motor

OFF

#2

Dump Valve

OFF

#3

Gear Motor

ON

#4

Water Float Valve Solenoid Coil

OFF

Revised 8/2003