Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 61

Advertising
background image

Section 5

Troubleshooting

Part No. 80-1214-3

5-9

Evaporator Removal

QF400

The evaporator and motor / gearbox are separate
assemblies. Warranty procedures require replacement
of the entire evaporator or motor /gearbox assembly.
Separate components are not available, and field
rebuilding during the warranty period is not allowed.

1. Disconnect power to the ice machine.

2. Remove water level probes, water reservoir cover,

float valve, water reservoir, ice chute, and drain
tubing (refer to Component Removal).

3. Recover refrigerant and disconnect refrigeration

tubing from evaporator.

4. Remove foundation-coupling bolts.

5. Lift evaporator out of foundation coupling and

remove from ice machine.

6. Remove spline hub and keyway from evaporator.

7. Apply anti-seize compound to the shaft and all bolts

to ease future disassembly.

8. After reinstallation of evaporator, torque foundation

bolts to 195-205 inch lbs.

QC700/QF800

The evaporator and motor / gearbox are separate
assemblies. Warranty procedures require replacement
of the entire evaporator or motor /gearbox assembly.
Separate components are not available, and field
rebuilding during the warranty period is not allowed.

1. Disconnect power to the ice machine.

2. Remove water level probes, water reservoir cover,

float valve, water reservoir, ice chute, and drain
tubing (refer to Component Removal).

3. Recover refrigerant and disconnect refrigeration

tubing from evaporator.

4. Remove foundation-coupling bolts.

5. Lift evaporator out of foundation coupling and

remove from ice machine.

6. Remove spline hub and keyway from evaporator.

7. Apply anti-seize compound to the shaft and all bolts

to ease future disassembly.

8. After reinstallation of evaporator, torque foundation

bolts to 195-205 inch lbs.

REMOVE

FOUNDATION BOLTS

SV2046

SV3057

REMOVE

FOUNDATION BOLTS

Revised 8/2003