Rfc2385 – Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 95

Advertising
background image

Section 6

Electrical System

Part No. 80-1214-3

6-33

RFC2385

Automatic Shut-Off

When the refrigerant pressure is low
enough to open the low-pressure
switch, the contactor coil is de-
energized and the compressor and
condenser fan motor stop.

SV2121

RUN

CAPACITOR

(50)

(43)

(48)

COMPRESSOR

RUN

CAPACITOR

(47)

(46)

(49)

(44)

START

CAPACITOR

RELAY

S

C

R

5

2

1

(45)

OVERLOAD

CONTACTOR

CONTACTS

CONTACTOR

CONTACTS

CONTACTOR

COIL

LOW PRESSURE

CUT-OUT

HIGH PRESSURE

CUT-OUT

(96)

(94)

GROUND

L1

L2

COMPRESSOR

CRANKCASE

HEATER

(95)

(74)

FAN MOTOR

(85)

C1

C2

3. Automatic Shut-Off (45 Seconds)

High Pressure Control

CLOSED

Low Pressure Control

OPEN

Contactor Coil

OPEN / OFF

Compressor

OFF

Condenser Fan Motor

OFF

Revised 8/2003