Electrical System

Section 6

6-20

Part No. 80-1214-3

QF2200

Freeze Cycle

2. FREEZE

The gear motor, liquid line solenoid
valve and water float valve solenoid
remain energized as the ice machine
makes ice. The water float valve will
open and close automatically to
maintain the proper water level.

SV3046

RELAY

K1

RELAY

K2

RELAY

K3

RELAY K4

(25)

L1

L2

(54)

(53)

LIQUID LINE

SOLENOID

CENTRIFUGAL

SWITCH

(65)

INTERNAL

OVERLOAD

START

RUN

GEARMOTOR

WATER FLOAT

VALVE COIL

DUMP VALVE

COIL

(56)

(55)

(22)

(51)

(52)

7 AMP

FUSE

GROUND

2. Freeze (Until Ice Contacts Bin Level Probe for 30 Continuous Seconds)

Toggle Switch

ICE

Bin Level Probe

Open (No Ice Contact)

Control Board Relays

#1

Liquid Line Solenoid Valve

ON

#2

Dump Valve

OFF

#3

Gear Motor

ON

#4

Water Float Valve Solenoid Coil

ON

Revised 8/2003