Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 115

Advertising
background image

Section 6

Electrical System

Part No. 80-1214-3

6-53

CONTROL BOARD RELAYS

Function

The control board relays energize and de-energize
system components.

Specifications

Relays are not field replaceable. There are four relays on
the control board:

Check Procedure

1. Leave all wiring connected and refer to the

Energized Parts Chart. Then verify:

A. The relay should be energized.

B. The red control board LED is energized for the

relay contacts being tested.

2. Check for line voltage at the control board.

A. Insert one electrical test lead to test L2 (wire

#22).

B. Insert one electrical test lead to test for voltage

through the contacts.

MAIN FUSE

Function

The control board fuse stops ice machine operation if
electrical components fail, causing high amp draw.

Specifications

The main fuse is 250 Volt, 10 amp.

Check Procedure

1. If any control board lights are energized, the fuse is

good.

2. Remove the fuse. Check the resistance across the

fuse with an ohm meter.

Relay

Controls

#1

Contactor Coil

#2

Water Dump Valve

#3

Gear Motor

#4

Float Valve Coil

Voltage Reading

Result

Line Voltage*

Relay is good.

No Voltage

Relay is defective.

Replace control board.

*Refer to model/serial label for correct voltage.

INSERT

TEST LEAD.

RELAY

CONTACTS

WIRE

#90

L2

WIRE #22

INSERT

TEST LEAD.

!

Warning

High (line) voltage is applied to the control board
(terminals #21 and #22) at all times. Removing the
control board fuse or moving the toggle switch to OFF
will not remove the power supplied to the control
board.

!

Warning

Disconnect electrical power to the entire ice machine
before proceeding.

Reading

Result

Open (OL)

Replace fuse.

Closed (O)

Fuse is good.