3 operational checks – Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 33

Advertising
background image

Section 3

Ice Machine Operation

Part Number 80-1214-3

3-3

Operational Checks

GENERAL

Manitowoc ice machines are factory-operated and
adjusted before shipment. Normally, a newly installed ice
machine does not require any adjustment.

To ensure proper operation, always follow the
Operational Checks:

when starting the ice machine for the first time

after a prolonged out of service period

after cleaning and sanitizing

NOTE: Routine adjustments and maintenance
procedures outlined in this manual are not covered by
the warranty.

WATER LEVEL CHECK

The float valve maintains the correct water level. The
water level must allow the water level probes to maintain
water contact throughout the freeze cycle. The water
level is factory set and normally will not require
adjustment. Check the water level during the freeze
cycle. The water level is correct if the water level
indicator light is energized (compressor is running) and
no water is entering the overflow tube. (Check for
overflow water exiting the ice machine drain line at the
floor drain).

If adjustments are necessary:

A. Rotate float clockwise to increase water level

B. Rotate float counterclockwise to decrease water

level

C. Verify the outlet for the water float valve is at a

20 to 30 degree angle to prevent contact with
the float.

SV2029

VERIFY WATER

OUTLET DOES

NOT POINT

STRAIGHT

DOWN IT MAY

INTERFERE

WITH FLOAT

WATER LEVEL

PROBE

WATER FLOAT

ROTATE TO

ADJUST WATER

LEVEL

WATER FLOAT

VALVE

WATER FLOAT

VALVE SOLENOID

COIL

Advertising
This manual is related to the following products: