Electrical System

Section 6

6-18

Part No. 80-1214-3

QF2200

Initial Start-Up

1B. WATER FILL

After 45 seconds the water float valve
solenoid is energized. When water
contacts the water level probe the
liquid line solenoid valve energizes
and remains on throughout the
Freeze Cycle.

SV3044

RELAY

K1

RELAY

K2

RELAY

K3

RELAY K4

(25)

L1

L2

(54)

(53)

LIQUID LINE

SOLENOID

CENTRIFUGAL

SWITCH

(65)

INTERNAL

OVERLOAD

START

RUN

GEARMOTOR

WATER FLOAT

VALVE COIL

DUMP VALVE

COIL

(56)

(55)

(22)

(51)

(52)

7 AMP

FUSE

GROUND

1B. Water Fill (Until Water Contacts Water Level Probe)

Toggle Switch

ICE

Bin Level Probe

Open (No Ice Contact)

Control Board Relays

#1

Liquid Line Solenoid Valve

OFF

#2

Dump Valve

OFF

#3

Gear Motor

ON

#4

Water Float Valve Solenoid Coil

ON