Section 6

Electrical System

Part No. 80-1214-3

6-25

QF2200

Automatic Shut-Off

An 8 minute lockout starts when the
compressor de-energizes. When the
ice drops away from the bin level
probe the ice machine will begin an
initial start-up cycle, provided the “8
minute lockout” has expired.

8 Minute Lockout

The bin level light will flash until the 8
minute lockout expires. After the 8
minute lockout time can be
overridden by moving the ON/OFF/
CLEAN toggle switch for ICE to OFF
and back to ICE.

SV3048

RELAY

K1

RELAY

K2

RELAY

K3

RELAY K4

(25)

L1

L2

(54)

(53)

LIQUID LINE

SOLENOID

CENTRIFUGAL

SWITCH

(65)

INTERNAL

OVERLOAD

START

RUN

GEARMOTOR

WATER FLOAT

VALVE COIL

DUMP VALVE

COIL

(56)

(55)

(22)

(51)

(52)

7 AMP

FUSE

GROUND

Automatic Shut-Off (Until Ice No Longer Contacts Bin Level Probe)

Toggle Switch

ICE

Bin Level Probe

CLOSED ( Ice Contacting probe)

Control Board Relays

#1

Liquid Line Solenoid Valve

OFF

#2

Dump Valve

OFF

#3

Gear Motor

OFF

#$

Water Float Valve Solenoid Coil

OFF

Revised 8/2003