Electrical System

Section 6

6-24

Part No. 80-1214-3

QF2200

Automatic Shut-Off

3B. WATER DRAIN

To allow water to drain from the
evaporator, the dump valve energizes
for 90 seconds, then de-energizes.

An 8 minute lockout starts when the
compressor de-energizes. When the
ice drops away from the bin level
probe the ice machine will begin an
initial start-up cycle, provided the “8
minute lockout” has expired.

SV3048

RELAY

K1

RELAY

K2

RELAY

K3

RELAY K4

(25)

L1

L2

(54)

(53)

LIQUID LINE

SOLENOID

CENTRIFUGAL

SWITCH

(65)

INTERNAL

OVERLOAD

START

RUN

GEARMOTOR

WATER FLOAT

VALVE COIL

DUMP VALVE

COIL

(56)

(55)

(22)

(51)

(52)

7 AMP

FUSE

GROUND

3B. Water Drain (90 Seconds)

Toggle Switch

ICE

Bin Level Probe

CLOSED ( Ice Contacting probe)

Control Board Relays

#1

Liquid Line Solenoid Valve

OFF

#2

Dump Valve

ON

#3

Gear Motor

OFF

#$

Water Float Valve Solenoid Coil

OFF