Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 92

Advertising
background image

Electrical System

Section 6

6-30

Part No. 80-1214-3

QF2300 Ice Machine Head Section

Freeze Cycle

2. FREEZE

When water contacts the water level
probe the liquid line solenoid valve,
equalization valve, compressor and
condenser fan motor energize. The
gear motor, compressor, condenser
fan motor and water float valve
solenoid remain energized as the ice
machine makes ice. The water float
valve will open and close
automatically to maintain the proper
water level.

SV2111

RELAY

K1

RELAY

K2

RELAY

K3

RELAY K4

(25)

L1

L2

(54)

(53)

LIQUID LINE

SOLENOID

CENTRIFUGAL

SWITCH

(65)

INTERNAL

OVERLOAD

START

RUN

GEARMOTOR

WATER FLOAT

VALVE

DUMP VALVE

(56)

(55)

(22)

(51)

(52)

7 AMP

FUSE

GROUND

(58)

(57)

EQUALIZATION

SOLENOID

C2

C1

(91)

(22)

2. Freeze (Until Ice Contacts Bin Level Probe for 30 Continuous Seconds)

Toggle Switch

ICE

Bin Level Probe

Open (No Ice Contact)

Control Board Relays

#1

Liquid Line Solenoid Valve

ON

#2

Dump Valve

OFF

#3

Gear Motor

ON

#4

Water Float Valve Solenoid Coil

ON

Revised 8/2003