Electrical System

Section 6

6-58

Part No. 80-1214-3

Diagnosing Start Components

If the compressor attempts to start, or hums and trips the
overload protector, check the start components before
replacing the compressor.

CAPACITOR

Visual evidence of capacitor failure can include a
bulged terminal end or a ruptured membrane. Do not
assume a capacitor is good if no visual evidence is
present.

A good test is to install a known good substitute
capacitor.

Use a capacitor tester when checking a suspect
capacitor. Clip the bleed resistor off the capacitor
terminals before testing.

RELAY

The relay has a set of contacts that connect and
disconnect the start capacitor from the compressor start
winding. The contacts on the relay are normally closed
(start capacitor in series with the start winding). The
relay senses the voltage generated by the start winding
and opens the contacts as the compressor motor starts.
The contacts remain open until the compressor is de-
energized.

Relay Operation Check

1. Disconnect wires from relay terminals.

2. Verify the contacts are closed by checking for

continuity between terminals:

No continuity indicates open contacts. Replace the
relay.

3. Check the relay coil. Measure the resistance

between terminals:

No resistance indicates an open coil. Replace the
relay.

4. Replace control box cover and restore electrical

power to the ice machine.

5. Move toggle switch to the ICE position.

6. The compressor start winding should energize for

less than 1 second. Continued high amperage draw
could indicate:

Low incoming power supply (Check voltage at
compressor start-up when load is greatest)

Defective relay

Defective capacitor

Defective compressor

Verify voltage and replace all start components.

7. If all of the previous tests are satisfactory and the

compressor will not operate or continue to operate,
replace the compressor.

!

Warning

Disconnect electrical power to the condensing unit
before proceeding.

QF400

QC700/QF800

RFC2085/

RFC2385

(QF2200/QF2300)

10 & 11

1 & 2

1 & 2

QF400

QC700/QF800

RFC2085/

RFC2385

(QF2200/QF2300)

10 & 11

1 & 2

1 & 2

!

Warning

Replace control box cover before proceeding.

Revised 8/2003

Advertising
This manual is related to the following products: