Serial port

23

Advanced
parameters

The parameters are presented in the following manner:

This tab is used to configure the line type:

l

PC: uses the driver to connect to a series 7 PLC terminal port,

l

Uni-Telway: default value, uses the driver to communicate in Uni-Telway,

l

Num PLC: uses the driver to connect to NUM PLCs.

l

RX/TX Delay: by default set to –1; is used to extend the return time (if the
station is too fast).

l

Link Timeout: by default set to –1; is used to set the maximum time for
detecting the right transmission speed.

l

Force Virtual Com Port: must be checked if the Unit-Telway driver uses a virtual
communication port except for use with the TSX PCX 3030 cable.

Link Parameters

Advanced

Uni-Telway

OK

Cancel

Parameters of the Station

TimeOut Link

RX/TX Delay

Type of link

Other

PC

Uni-Telway

PCL No.

-1

-1

Force Virtual Com Port