TSX FPC 10 ISA card

59

4

Click on Change settings.

Result

The following window appears:

5

From the Value list, select the non-conflicting address range.

Note: note the values because they must be coded onto the ISA card.

6

Confirm with OK.

7

Carry out steps 5 to 8 selecting Interrupt Request from the list.

8

Confirm with Ok then restart the station with the card connected.

Step

Action

Modify input/output range

Enter the input/output range you wish to define for this
peripheral.

You can either enter a specific range and the closest valid
range will be automatically selected, or select a range using
the indicator arrows.

?

No peripherals in conflict.

Value:

The parameter you have chosen is not in conflict with
other peripherals.

01A0-01AF

OK

Cancel