Chapter 6, Relation between parts, 6relation between parts – Nortel Networks DCT1900 User Manual

Page 135: Hapter

Advertising
background image

Technical Product Manual - DCT1900

Configuration Directions, Relation between Parts

Config-DCT1900/R8/mw

6-1

© 2000-2005

C

HAPTER

6

Relation between Parts

Radio Exchange

Item Connects

Remarks

Modular Cabinet

9 System Boards

1 Connection Board

2 Power Supplies

Number of System Boards may be less due to
power limitations. Up to 4 cabinets can be chained.

An MCCB is factory mounted.

CPU

PC, Printer, General Alarm, SMS
and PWT air interface
synchronization signals

Only 1 per system (also with a multi–cabinet
system).

CPU/SDB synchronization cables.
Note: Sync Kit required for each CPU. FPGA
must be installed.

SLU 8

calls

8 Base Stations

An SLU consists of an SPU part and a CLU part.
The SLU can be combined with SPU and CLU
boards.

The SPU part provides for 8 speech paths. The CLU
part can connect 8 Base Stations.

CLU/MDF Cables and CLU/MCCB Power cables.

Quantity depends on required traffic capacity and
GOS.

DTU-E1, CCS

60 simultaneous calls

Two 2–Mbit links, each link having 30 channels to
which Portable Telephones are assigned
dynamically. The maximum number of Portable
Telephones depends on the GOS and the traffic
capacity of the RE configuration (1 per RE)

DTU-T1, CCS

46 simultaneous calls

Two 1.544-Mbits, each link having 23 channels to
which Portable Telephones are assigned
dynamically. The maximum number of Portable
Telephones depends on the GOS and the traffic
capacity of the RE configuration (1 or 2 per RE).

DTU-E1, CAS

60 individual extensions

Two 2–Mbit links, each link having 30 channels to
which Portable Telephones are assigned on a
dedicated basis. (Max. 10 per system)

DTU-T1, CAS

48 individual extensions

Two 1.544-Mbits, each link having 24 channels to
which Portable Telephones are assigned on a
dedicated basis. (Max. 13 per system)

LTU

8 PBX lines (analog, 2 wires)

LTU/MDF Cable Set- 1 cable supports 3 LTUs . A
maximum of 272 Portable Telephones supported.

DLU

12 PBX lines (1:1 digital lines)

DLU/PBX Cable Set- 1 cable supports 2 DLUs. Each
DLU supports 12 Portable Telephones.

CLU

8 Base Stations – 2.2 miles

CLU/MDF Cables and CLU/MCCB power cables.

CLU-S

8 Base Stations – 1.2 miles

SPU

8 calls

The SPU provides 8 speech paths. Quantity
depends on required traffice and GOS.

MCCB

3+7 CLU or 3+7 SLU power ports
for Base Station power

PC, Printer/SMS and General
Alarm

Modular Cabinet Connection Board

SDB

1 input and 3 output PWT air
interface synchronization
connections

To be mounted on the bottom plate of the Modular
Cabinet.

Advertising