Safety

1.1

General

z

Never install telephone wiring during a lightning storm.

z

Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.

z

Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.

z

Note: Avoid touching or punching down the Base Station signal and power pairs as there is
-48Vdc present on these wires at all times.

z

Use caution when installing or modifying telephone lines.

z

Avoid using a telephone (other than a cordless type) during an electrical storm. Electric shock
from lightning may occur.

z

Do not use the telephone to report a gas leak in the vicinity of the leak.

z

Installation should conform to relevant national installation rules.

z

The Modular Cabinet should be mounted in a restricted area.

z

Do not mount the modular cabinet to a drywall using insertable plastic drywall plugs. These
will not safely support the cabinet. See Installation section for recommended mounting.

z

Suitable for mounting on concrete or other non-combustible surface only. [This refers to the
floor covering/material beneath the cabinet(s)].

z

Disconnect all power sources before servicing equipment.

z

For the Modular Cabinet use Class II power sources (double insulated, conforms to UL1950,
Uout

58 Vdc) only. The power source branch circuit over current protection must be rated

15A. The power source must be short circuit protected (15A maximum).

z

A readily accessible disconnect device, that is suitably approved and rated, shall be
incorporated in the field wiring.

z

Connect to a reliably grounded -48Vdc SELV source.

z

Use minimum 14 AWG copper conductors.

z

Service is to be performed by qualified personnel only.

z

Torque power supply terminal block screws to 7 in. - lbs

z

The safety status of the different interconnection points of the system are as follows:
-

RS232A, RS232B ports: SELV circuits

-

Power Failure and General Alarm contacts: SELV circuits

-

Digital Trunk Unit (DTU) connections: TNV circuits

-

Digital Link Unit (DLU) connections: TNV circuits

-

Base Station connections: TNV circuits

-

Sync ports Central Processing Unit (CPU): SELV circuits