Technical Product Manual - DCT1900

Safety and Regulatory Information, Safety

Safety-DCT1900/R8/mw

1-1

© 2000-2005

C

HAPTER

1

Safety

1.1

General

z

Never install telephone wiring during a lightning storm.

z

Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.

z

Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.

z

Note: Avoid touching or punching down the Base Station signal and power pairs as there is
-48Vdc present on these wires at all times.

z

Use caution when installing or modifying telephone lines.

z

Avoid using a telephone (other than a cordless type) during an electrical storm. Electric shock
from lightning may occur.

z

Do not use the telephone to report a gas leak in the vicinity of the leak.

z

Installation should conform to relevant national installation rules.

z

The Modular Cabinet should be mounted in a restricted area.

z

Do not mount the modular cabinet to a drywall using insertable plastic drywall plugs. These
will not safely support the cabinet. See Installation section for recommended mounting.

z

Suitable for mounting on concrete or other non-combustible surface only. [This refers to the
floor covering/material beneath the cabinet(s)].

z

Disconnect all power sources before servicing equipment.

z

For the Modular Cabinet use Class II power sources (double insulated, conforms to UL1950,
Uout

≤

58 Vdc) only. The power source branch circuit over current protection must be rated

15A. The power source must be short circuit protected (15A maximum).

z

A readily accessible disconnect device, that is suitably approved and rated, shall be
incorporated in the field wiring.

z

Connect to a reliably grounded -48Vdc SELV source.

z

Use minimum 14 AWG copper conductors.

z

Service is to be performed by qualified personnel only.

z

Torque power supply terminal block screws to 7 in. - lbs

z

The safety status of the different interconnection points of the system are as follows:
-

RS232A, RS232B ports: SELV circuits

-

Power Failure and General Alarm contacts: SELV circuits

-

Digital Trunk Unit (DTU) connections: TNV circuits

-

Digital Link Unit (DLU) connections: TNV circuits

-

Base Station connections: TNV circuits

-

Sync ports Central Processing Unit (CPU): SELV circuits