Nortel Networks DCT1900 User Manual

Page 392

Advertising
background image

Technical Product Manual - DCT1900

Maintenance, Fault Finding Procedures

6-10

Maint-DCT1900/R8/mw

© 2000-2005

ERRORS

System List Error

Buzzer Data

Error

Fixed Phone

book Error

User Data Error

Initialization Error

END

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Initialization data missing or
corrupted. Re-initialize Portable
Telphone.

Ringing cadence data missing
or corrupted. Re-initialize
Portable Telephone.

Fixed phone book data missing or
corrupted. If phone book was loaded, all
data is lost. Re-download phone book.

User data corrupted. All data (preferences) will be
replaced with defaults, speed dial numbers will be
cleared. This fault occurs only once; after cycling the
power the fault disappears, because defaults are set.

Error occured during initialization process.
Restart initialization.

1) For all faults correction actions are given.

If after correction a fault re-appears, the
Portable Telphone should be sent for repair.