Nortel Networks DCT1900 User Manual

Page 185

Advertising
background image

Technical Product Manual - DCT1900

Product Specifications, System Boards

Specs-DCT1900/R8/mw

6-5

© 2000-2005

6.7

Speech Processing Unit, SPU-S - REX-BRD0017 or ROFNB 157 16/3

Environmental
Temperature

Operating

: 32 to 104

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications
Length x width

13.5" x 7.7" (343 x 195.6mm)

Speech Coding
Telephone exchange side

: 64 kbit/s PCM (A–law or

μ–law, country dependent,

downloaded from CPU)

Base Stations side

: 32 kbit/s ADPCM

DTMF Levels
Country dependent (downloaded from CPU)

Artificial Leakage
Only if a DTU is used

: -24 dB

Dial Tone Detection
Sensitivity level

: -29 dBm

Detection time

: 800 ms

Frequencies

: 350/440 Hz

6.8

Cell Link Unit, CLU - REX-BRD0014 or ROFNB 157 11/2

Environmental
Temperature

Operating

: 32 to 104

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non-condensing

Fusing
Power to the Base Stations is fused by two replaceable 1.0 AT fuses per Base Station.

Transport Data Rate
384 kbit/s

General Specifications
Length x width

13.5" x 7.7" (343 x 195.6mm)

Advertising