Technical Product Manual - DCT1900

Maintenance, Fault Finding Procedures

6-6

Maint-DCT1900/R8/mw

© 2000-2005

COMMON USER

COMPLAINT

All Portables

out of range?

Green LED on
all Boards on?

Yes

Yes

CPU

Portables

of one area out

of range?

No

No

Complaints

come from same

area?

Yes

PSU of associated
cabinet

No

Blocked calls?

No

No

INDIVIDUAL USER

COMPLAINT

Yes

Yes

Poor coverage of an area
caused by lack of Base
Stations, a malfunctioning
Base Station or no air
interface synchronization
between adjacent systems

Lack of resources in
Base Stations or SPUs

Check fuses at

power switch
Check power

source

Fuses and

power source

okay?

No

Yes

Replace fuse or repair
power source

Replace Backplane

1) A malfunctioning Base Station can be detected by:

y

testing the Base Station with the Portable Telephone in the
Service Display Mode (see Paragraph 3.8) or

y

checking the load of the Base Station by System Manager-
Statistics-Display-Station-Station Load or

y

checking the operation of the Base Stations by System
Manager-Statistics-Settings-View on Line

2) When going off hook on the Portable Telephone, the hook symbol

on the display does not become stable and the Portable
Telephone automatically goes on hook.