12 digital line unit, dlu - rex-brd0023 – Nortel Networks DCT1900 User Manual

Page 90

Advertising
background image

Technical Product Manual - DCT1900

Product Specifications, System Boards

6-10

Specs-DCT1900/R8/mw

© 2000-2005

6.12

Digital Line Unit, DLU - REX-BRD0023

AWS1024 Meridian, AWS1025 Norstar, AWS1026 Lucent

The DLU has 12 analog front ends (ports) that provide 12 digital line interfaces to the PBX.

Compliance to Regulations and Standards
Safety

: ANSI/UL 60950
: CSA 22.2-950 3rd edition

Electrostatic discharge

: EN 61000-4-2

Radiated susceptibility

: EN 61-4-3

Electrically Fast
Transients (burst)

: EN 61000-4-4

Conducted disturbances

: EN 61000-4-6

Radiated and
Conducted Emissions

: EN 55022, procedure CISPR 22 and CISPR 16 Class A

Environmental
Temperature

Operating

: 32 to 158

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 95% max, non condensing at 77 to 158

°F (25 - 70°C)

General Specifications
Length x width

: 13.0" x 7.0 x 0.79" (340 x 178 mm)

Maximum Power Consumption : 3.0 W at 5V

1.2 W at -12V

RS232 serial port

: 1 via a DB9 female connector

Digital Line Specification
Number of digital
interfaces per DLU

: 12

Bit rate

: Automatically adjusted for the PBX type it is configured for.

Signalling

: Proprietary digital signal encoding.