Nortel Networks DCT1900 User Manual
Page 324

Technical Product Manual - DCT1900
Installation Instructions, Modular Cabinet – Cables
26-20
Install-DCT1900/R8/mw
© 2000-2005
26.16 DTU/MDF Twisted Pair Cable – TSRNB 101 50 or AWS1034 (T1 - 100 ohm)
The DTU/MDF twisted pair cable AWS1034 (see Figure 26–19) consist of a 100 ohm shielded
cable terminated with two connectors. The cable is used to connect a DTU to a MS or PBX via a
MDF (Main Distribution Frame). The shielding of the cables is connected to the cabinet via a
clamp which also functions as a strain relief. The length of the cable is 16 ft. Excess cable length
may be trimmed at installation.
The TSRNB 101 50 cable is terminated at one end in 2 RJ45 connectors. These should be cut off
to allow for punch down.
WHT
WHT
WHT
BRN
GRN
1 2
7
8
WHT
WHT
ORN
BLU
1 2
7
8
WHT
WHT
WHT
ORN
BLU
1 2
7
8
X2
X1
RCV
pairs
XMIT
pairs
View looking into DTU board edge
X1
X2
White/Blue pair
White/Orange pair
White/Green pair
White/Brown pair
Shield clamp
(K1)
(K2)
(1034 cable)
Fig. 26–19 DTU Twisted Pair Cable - T1