Installation Instructions, Modular Cabinet – Cables

26-14

Install-DCT1900/R8/mw

© 2000-2005

26.11 LTU/MDF Cable Set – NTM/TSRNB 101 31

The LTU/MDF Cable Set (see Figure 26-13) is used for the connection of the LTU to an MDF. It
consists of two shielded cables with a connector at one side. The shield of the cable is connected
to the Modular Cabinet by a clamp. The only difference between the two cables is the location of
this clamp on the cable. The clamp is placed on respectively 14 in. from the connector for the
TSRNB 101 31/1, and 19 in. for the TSRNB 101 31/2. The clamp also functions as a pull relief.
The length of the cable is 16.40 ft.

Fig. 26–13 LTU/MDF Cable Set – NTM/TSRNB 101 31