Technical Product Manual - DCT1900

Installation Instructions, Modular Cabinet – Cables

Install-DCT1900/R8/mw

26-19

© 2000-2005

26.15 DTU Twisted Pair Cable Set – NTM/TSRNB 101 49 or AWS1033 (E1-120 ohm)

The DTU twisted pair cable AWS1033 (see Figures 26–18) consists of a 120 ohm shielded cable
terminated with two connectors. The cable is used to connect a DTU-E1 to a MS or PBX via a
MDF(Main Distribution Frame). The shielding of the cables is connected to the cabinet via a clamp
which also functions as a strain relief. The length of the cable is 16ft. Excess cable length may be
trimmed at installation.

Fig. 26–18 DTU Twisted Pair Cable - E1

WHT

WHT

WHT

BRN

GRN

1 2

7

8

WHT

WHT

ORN

BLU

1 2

7

8

WHT

WHT

WHT

ORN

BLU

1 2

7

8

X2

X1

RCV
pairs

XMIT
pairs

View looking into DTU board edge

X1

X2

White/Blue pair

White/Orange pair

White/Green pair

White/Brown pair

Shield clamp