Technical Product Manual - DCT1900

Product Specifications, System Boards

6-2

Specs-DCT1900/R8/mw

© 2000-2005

6.2

Digital Trunk Unit, DTU-T1, CAS - REX-BRD0021 or 2/ROFNB 157 13/2

Compliance to Regulations and Standards
The DTU–T1 provides 2 standard T1 interfaces. The DTU–T1 complies with the following EIA/TIA
recommendation:

EIA/TIA 464

: Private Branch Exchange (PBX) Switching Equipment for

Voice–band Applications.

Environmental
Temperature

Operating

: 32 to 104

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications
Length x width

13.5" x 7.7" (343 x 195.6mm)

Digital Trunk Specification
Number of T1
interfaces per DTU

: 2

Bit rate

: 1.544 Mbit/s

Signalling

: Channel Associated Signalling with bit Robbing (CAS BR)

according to EIA/TIA 464–A FXS DSX–1, using firmware set
RYS 105 660

6.3

Digital Trunk Unit -DTU–T1,CCS - REX-BRD0021 or 2/ROFNB 157 13/3

The DTU–T1 provides 2 standard T1 interfaces. The DTU–T1 complies with the following EIA/TIA
recommendation:

EIA/TIA 464

: Private Branch Exchange (PBX) Switching Equipment for

Voice–band Applications.

Environmental
Temperature

Operating

: 32 to 104

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications
Length x width

13.5" x 7.7" (343 x 195.6mm)

Digital Trunk Specification
Number of T1
interfaces per DTU

: 2

Bit rate

: 1.544 Mbit/s

Signalling

: Common Channel Signalling with a 64Kbps D channel using

Q.931 protocol with proprietary extensions for mobility
management, using firmware RYS 105 650.