Table 23 interpreting npd/id numbers – Nortel Networks NN43001-106 User Manual

Page 421

Advertising
background image

Feature interactions

421

Table 23 "Interpreting NPD/ID numbers" (page 421)

shows an example of

an NPID table. The last two fields, ANI Failure and Test Calls, are mutually
exclusive. If the NPD/ID digit 0 is interpreted as ANI failure, it cannot also
be interpreted as a test call.

Table 23
Interpreting NPD/ID numbers

NPI/Info Digit

NPA

ANI Failure

Test Call

0

408

No

No

1

415

No

No

2

NONE

No

No

3

NONE

No

No

4

NONE

No

No

5

NONE

No

No

6

NONE

No

No

7

NONE

Yes

No

8

NONE

No

Yes

9

NONE

No

No

If the NPA is not specified (NPA = NONE), the NPD/ID digit appears on the
telephone. Otherwise, the NPA appears on the telephone for calls with
a valid ANI.

Seven zeros indicate a failure (for example, MF receive fault, garbled tones
or a timeout). After all ANI digits are received or a timeout occurs, the
system processes the call.

A test call has no display.

Trunk route assignments

The 911 trunk must auto-terminate to a Controlled Directory Number (CDN)
defined in LD 23. The start arrangement must be WINK and the Class
of Service must be defined as Priority Trunk (APY) and Multifrequency
Receiver (MFR).

ANI failure

If ANI information is incorrectly delivered, the call may not have a valid ANI,
as indicated by the seven zeros in the display.

ANI failure affects the incoming call’s Application Module Link (AML)
message, which informs the application with a special DN type value. The
911 caller’s DN type Information Element (IE) contains one of these types:
ANI with NPD, ANI with ID or ANI failure.

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.

Advertising