481

Prompt

Response

Description

CODE

MWUD

Multiple Wake Up deactivation.

- MWUD

xxxx

Multiple Wake Up deactivation code Analog (500/2500 type)
telephones.
MWUD is prompted until <CR> is entered.

LD 56 - Set Automatic Wake Up special error tone and configuration tone.

Prompt

Response

Description

REQ

NEW
CHG

Add new data.
Change existing data.

TYPE

FTC

Flexible Tones and Cadences data block.

TABL

0-31

Flexible Tones and Cadences (FTC) Table Number. To
associate a FTC table with trunk route, enter the table number
in response to the TTBL prompt in LD 16.

...

HCCT

YES

Hardware Controlled Cadences and Tone modification of the
hardware controlled cadence tone definitions allowed.

...

- FFCT

Flexible Tone and Cadence.

- - XTON

xxx

Flexible Tone and Cadence confirmation tone.
China xxx = 211
North America xxx = 004

- - XCAD

xxx

Cadence code for Firmware Cadence Table (FCAD) as entered
at Cadence Number (WCAD) prompt.
China xxx = 110
North America xxx = 000

- AWUT

Automatic Wake Up.

- - XTON

xxx

Automatic Wake Up special error tone.
China xxx = 214
North America xxx = 007

- - XCAD

xxx

Cadence code for Firmware Cadence Table (FCAD) as entered
at Cadence Number (WCAD) prompt.
China xxx = 100
North American xxx = 017

Feature operation

The following feature operations occur if the WUD prompt (Wake Up
Delimiter) and STE prompt (Standard Time Entry) are set to YES in LD 15.
If WUD = YES and STE = NO, then the user must dial all four standard time
digits and an octothorpe for a valid entry. If WUD = NO then the STE prompt
will not appear. In this case, the prior operation exists and the user is not
expected to enter the delimiter (#) at the end of time entry. However, all four

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.