Texas Instruments TMS320C64x DSP User Manual

Page 113

Advertising
background image

Video Capture Registers

3-51

Video Capture Port

SPRU629

Table 3–14. Video Capture Channel x Status Register (VCxSTAT)

Field Descriptions

Description

Bit

field

symval

Value

BT.656 or Y/C Mode

Raw Data Mode

TSI Mode

31

FSYNC

Current frame sync bit.

CLEARD

0

VCOUNT = VINT1 or
VINT2, as selected
by the FSCL2 bit
in VCxVINT.

Not used.

Not used.

SET

1

VCOUNT = 1
in field 1.

Not used.

Not used.

30

FRMC

Frame (data) captured bit. Write 1 to clear the bit, a write of 0
has no effect.

NONE

0

Complete frame has
not been captured.

Complete data
block has not
been captured.

Entire data packet
has not been
captured.

CAPTURED

CLEAR

1

Complete frame has
been captured.

Complete data
block has been
captured.

Entire data packet
has been
captured.

29

F2C

Field 2 captured bit. Write 1 to clear the bit, a write of 0 has no
effect.

NONE

0

Field 2 has not been
captured.

Not used.

Not used.

CAPTURED

CLEAR

1

Field 2 has been
captured.

Not used.

Not used.

28

F1C

Field 1 captured bit. Write 1 to clear the bit, a write of 0 has no
effect.

NONE

0

Field 1 has not been
captured.

Not used.

Not used.

CAPTURED

CLEAR

1

Field 1 has been
captured.

Not used.

Not used.

† For CSL implementation, use the notation VP_VCxSTAT_field_symval