Texas Instruments TMS320C64x DSP User Manual

Page 61

Advertising
background image

Video Port Control Registers

Video Port

2-28

SPRU629

Table 2–9. Video Port Interrupt Status Register (VPIS) Field Descriptions (Continued)

Bit

Description

Value

symval

field

7

LFDA

Long field detected on channel A interrupt detected bit. (A long
field is only detected when the VRST bit in VCACTL is cleared to
0; when VRST = 1, a long field is always detected.)

BT.656 or Y/C capture mode – LFDA is set when long field
detection is enabled and VCOUNT is not reset before
VCOUNT = YSTOP + 1.

Raw data mode, or TSI capture mode or display mode – Not used.

NONE

0

No interrupt is detected.

CLEAR

1

Interrupt is detected. Bit is cleared.

6

SFDA

Short field detected on channel A interrupt detected bit.

BT.656 or Y/C capture mode – SFDA is set when short field
detection is enabled and VCOUNT is reset before
VCOUNT = YSTOP.

Raw data mode, or TSI capture mode or display mode – Not used.

NONE

0

No interrupt is detected.

CLEAR

1

Interrupt is detected. Bit is cleared.

5

VINTA2

Channel A field 2 vertical interrupt detected bit.

BT.656, or Y/C capture mode or any display mode – VINTA2 is set
when a vertical interrupt occurred in field 2.

Raw data mode or TSI capture mode – Not used.

NONE

0

No interrupt is detected.

CLEAR

1

Interrupt is detected. Bit is cleared.

4

VINTA1

Channel A field 1 vertical interrupt detected bit.

BT.656, or Y/C capture mode or any display mode – VINTA1 is set
when a vertical interrupt occurred in field 1.

Raw data mode or TSI capture mode – Not used.

NONE

0

No interrupt is detected.

CLEAR

1

Interrupt is detected. Bit is cleared.

† For CSL implementation, use the notation VP_VPIS_field_symval