Lcd panel used in character mode, Display command byte – Xilinx Virtex-5 FPGA ML561 User Manual

Page 135

Advertising
background image

Virtex-5 FPGA ML561 User Guide

www.xilinx.com

135

UG199 (v1.2.1) June 15, 2009

Hardware Schematic Diagram

R

LCD Panel Used in Character Mode

This design example requires a byte representing a command or data to be displayed as
input.

When the Enable signal is Low, nothing happens. The display interface design is
locked.

When the Enable signal is High and the data_or_command control signal is Low, the
byte written is a display command.

When the Enable signal and the data_or_command control signal are High, the byte
written is the ASCII character code of the character to be put on the display.

Display Command Byte

The command set of the display can be found in

Table C-6, page 130

.

When the LCD interface is enabled for the first time, a set of command bytes is sent to the
LCD. This command set provides the basic initialization of the LCD controller. When this
initialization is done, the normal LCD interface is freed for normal use. Command bytes
from the valid command set can be sent to the display (controller).

The Toplevel.vhd.txt file provides a detailed description of the LCD controller
interface.

Figure C-8:

General Block Diagram of LCD Panel in Full Graphics Mode

UG199_C_08_050106

Block RAM

IorD = '1' Instruction

'0' Data

Design for Full Graphics Interface, Attached to CoreConnect Bus

Enable

Write

Address

WData (32+4)

RData (8+gnd)

ena

Clock

read

Addr

IorD (bit 9)

DataIn (8)

DataOut (8)

RW

E

Clock

Reset

Clock

Reset

Clock

E

TC

RS

CS1B

DB (8)

CoreConnect

State

Machine

Clock