Calibrate ctrl, Table 6 – Printronix SL_T5R Energy Star User Manual

Page 127

Advertising
background image

MEDIA CONTROL Submenus

127

CALIBRATE CTRL

Gap/Mark

Sensor

1

Auto

Calibrate

Media

Profile

Disable

Mark

Gap

Advanced Gap*

Advanced Notch

Sensed

Distance

0.00 inches

2

Pwr Up

Action

Disable

Auto-Cal*

Seek TOF

Gap/Mark

Thresh

0000 to 1023

Gap Length

0.12 inches*

0.05 to 1.00 inches

Min Calib

Delta

080*

3

048 to 200

Use Label

Length

Enable*

Disable

Paper Out

Thresh

0000 to 1023

Manual

Calibrate

Online

Auto-Cal

Disable*

Enable

Gap

Windowing

Disable*

Enable

Cal in Peel

Mode

Disable*

Enable

Threshold

Range

50%*

5% to 95%

Run Calibrate

Print Profile

Paper Out

Sensor

1

Transmissive*

Reflective

Run Calibrate

Notes:

* = Factory Default

Italicized items are available only when you enable Admin User (in the PRINTER CONTROL menu).

1

Gap/Mark Sensor and Paper Out Sensor work in conjunction, as shown below:

If you change the Gap/Mark Sensor or Paper Out Sensor, you must recalibrate the media.

2

When Admin User is enabled (in the PRINTER CONTROL menu), you can change the unit value to millimeters:

Under the Units submenu (in the MEDIA CONTROL menu), enable the “In Millimeters” option.

3

When Gap/Mark Sensor = Disable, Gap, or Mark, the default is 48. When Gap/Mark Sensor = Advanced Gap or

Advanced Notch, the default is 80.

Table 6

When you select an
option in Gap/Mark
Sensor...

Paper Out Sensor
defaults to...

Disable

Reflective

Mark

Reflective

Gap

Reflective

Advanced Gap

Transmissive

Advanced Notch

Transmissive

HeadClose

Action

Disable*

Auto-Cal

Seek TOF

CALIBRATE

CTRL

(from page 85)

Advertising