Printronix SL_T5R Energy Star User Manual

Page 223

Advertising
background image

Emulation Submenus

223

User-Defined St1 (Start Code 1)

This option allows you to define your own value (in ASCII characters) for the
User Defined option in the Lead-in Chars menu. “St1” specifies Start Code 1.
See “Lead-in Chars” on page 208 for additional information.

The range is 40 - FF, and the factory default is 5F.

User-Defined St2 (Start Code 2)

This option allows you to define your own value (in ASCII characters) for the
User Defined option in the Lead-in Chars menu. “St2” specifies Start Code 2.
See “Lead-in Chars” on page 208 for additional information.

The range is 40 - FF, and the factory default is 5F.

User-Defined Stp (Stop Code)

This option allows you to define your own value (in ASCII characters) for the
User Defined option in the Lead-in Chars menu. “Stp” specifies Stop Code.
See “Lead-in Chars” on page 208 for additional information.

The range is 40 - FF, and the factory default is 5B.

Var Form Adjust

This specifies an amount (in tenths of inches) to add to the length of variable-
length forms. Variable-length forms use a semicolon at the end of the
CREATE command: ~CREATE;<FORMNAME>;0.

Typically, variable-length forms are determined by the elements within the
form. The longest form element becomes the overall form length. This option
allows an additional space to be added to the form length.

The range is 00.0 to 03.0 inches, and the factory default is 00.0 inches.

Var Form Type

Add Nothing

(factory default). When selected, no action is taken.

Add ;0

. When selected, the form length ends at the longest printed

element. (Same as

CREATE;filename;0)

Add ;X

. When selected, the form length is the same as the physical page

length (the Label Length menu under MEDIA CONTROL). (Same as

CREATE;filename;X)

VPA Check

Enable

(factory default). The printer checks for dots that fall outside the

intersection of the logical and physical pages. If dots fall outside the area,
the printer reports an error to the host if the IPDS Exception Handling
Control command setting requires error reporting.

Disable

. The printer does not report dots outside the valid printable area.

Advertising