Printronix SL_T5R Energy Star User Manual

Page 330

Advertising
background image

330

Chapter

6

Diagnostics for E0xx, Bad NVM, or ILL NVM Errors

SOFTWARE
ERROR*

Recycle Power

Yes/No

1.

Application
software tried to
perform an illegal
printer function.

2.

There are
damaged logic
circuits on the
controller PCBA.

1.

Recycle the printer power.
If possible, print a job that
has previously worked.

2.

If the problem persists,
contact your authorized
service representative.

Speed Exceeds

Validator Limit

Yes

The Print Speed or
Slew Speed value is
above 6 IPS as the
power-up default with
the validator option
installed, or the user
attempted to increase
Print Speed or Slew
Speed above 6 IPS.

Change the Print Speed or
Slew Speed value in the
MEDIA CONTROL menu to 6
IPS or less when using the
validator option, and save the
new value as the power-up
default.

TESTING
HARDWARE

PLEASE WAIT

Yes

Normal power-up
message. Printer is
running its initialization
routine.

1.

No action required.

2.

If the printer does not
complete initialization and
continues displaying this
message when the CT
emulation is installed, the
expansion CT board may
not be connected to the
controller PCBA.

Unscannable:

xx Missing Codes

Yes

Data validation error:

missing barcode.

Check the paper and ribbon for
cleanliness, wrinkles, etc., or
an obstructed validator beam.
If there is no validator beam at
all, or if the LED is not flashing
as barcodes pass through the
validator beam, recycle
validator power. If the problem
persists, contact your service
representative.

NOTE:

xx represents the
number of missing
barcodes (on the form)
that caused the
warning/fault to be
declared.

Table 18. LCD Message Troubleshooting (continued)

Displayed Message

Can User

Correct?

Explanation

Solution

Advertising