Running manual calibrate, Chapter 2 – Printronix SL_T5R Energy Star User Manual

Page 66

Advertising
background image

66

Chapter

2

Printing Adjustments

Running Manual Calibrate

Manual Calibrate should be performed only when the values derived from
Auto Calibrate fail to improve the media sensors’ ability to sense label length
indicators on the installed media. You must first enable “Admin User” in the
PRINTER CONTROL menu before accessing or initializing Manual Calibrate
in the CALIBRATE CTRL menu.

NOTE:

Verify the Gap/Mark Sensor option (Gap, Mark, Advanced Gap,
Advanced Notch, or Disable) matches the installed media. See
“Sensing Different Media Types” on page 59.

Ensure the media sensors are horizontally positioned to permit
sensing of the label length indicators. See “Positioning the Media
Sensors” on page 54
.

Ensure the Print Mode option selected in the QUICK SETUP menu
matches the media installed. Select “Direct” for heat sensitive media
(no ribbon required) or “Transfer” for thermal transfer media (ribbon
required).

If you try to do a Manual Calibrate when Peel-Off Media Handling is
enabled, the LCD will display, “CANNOT CALIBRATE/Disable Peel-
Off.” Before you can do a Manual Calibrate, you must select another
media handling mode.

1.

Press

to place the printer in Menu mode.

2.

Press the

↓ and

keys together until “ENTER SWITCH UNLOCKED”

displays.

3.

Press

until “PRINTER CONTROL” displays.

4.

Press

↑ until “Admin User” displays, then press

+

until “Enable” displays.

183416a

FEED

1023

0767

0511

0255

0000

Paper Out(301)

Gap(160)

Detected Amplitude

of the Antenna

Detected Amplitude

of the Gap

Media Sensor

Position

Indicates Type of Gap/Mark

Sensing Selected

..

.

..

.

Advertising