Offline process – Printronix SL_T5R Energy Star User Manual

Page 232

Advertising
background image

232

Chapter

3

PARALLEL PORT

Data Polarity

The Data Polarity parameter must be set to match the data polarity of your
host computer.

Standard

(factory default). Does not expect the host computer to invert

the data.

Inverted

. Expects the data received on the data lines from the host

computer to be inverted. Ones become zeros and vice versa.

Resp. Polarity

The Response Polarity parameter must be set to match the response polarity
of your host computer.

Standard

(factory default). Does not invert the response signal.

Inverted

. Inverts the response signal sent to the host computer.

Busy on Strobe

Enable

(factory default). Asserts a busy signal after each character is

received.

Disable

. Asserts a busy signal only when the print buffers are full.

Latch Data On

Specifies whether the data is read on the leading or trailing edge of the data
strobe signal.

The options are Leading (factory default) and Trailing.

Offline Process

Disable

(factory default). When set to disable, the printer does not

process parallel/network data while offline.

Enable

. When set to enable, the printer continues to process (but not

print) the current network/parallel job while the printer is offline until the
printer's buffer is full.