Alpha Technologies AMPS80 HP User Manual
Page 85

83
Doc. #: 026-069-B0 Rev F
Side Access Replacement
This is the preferred replacement procedure.
1. Turn off the inverter input breaker.
2. Remove the side access panel.
3. With the proper tools, reach in and remove
the screws holding the surge suppression
assembly.
4. Replace the module with an Alpha service
entrance grade surge suppression
assembly.
Front Access Replacement
1. Turn off the inverter input breaker.
2. Remove the screw securing the CXCR unit.
3. Remove the 4 mounting screws that hold
the CXCR to the chassis.
4. Pull the CXCR out and to the left. Do not
remove any of the wires from the CXCR.
5. Dangle CXCR unit gently.
6. With the proper tools, reach in and remove
the bolts holding the surge suppression
assembly.
7. Replace the module with an Alphaservice
entrance grade surge suppression
assembly.
Bolts holding surge
suppression assembly
Bolts holding surge
suppression assembly