Sensocheck

Continuously monitors the sensor and its wiring.

Sensocheck can be switched off.

Critical values make the Sensoface “sad” and the

corresponding icon blinks:

The Sensocheck message is also output as error message Err 33.

The alarm contact is active, the red LED is lit, output current 1 is

set to 22 mA (when configured correspondingly). Sensocheck can

be switched off during configuration (then Sensoface is also dis-

abled). Exception: After a calibration a smiley is always displayed

for confirmation.

Sensoface

The little smiley in the display (Sensoface) provides information

about the sensor condition (defects, maintenance required, cable

capacitance too high).

It alerts to significant sensor polarization or excessive cable

capacitance e.g. caused by an unsuitable cable or a cable that is

too long. The permitted calibration ranges and the conditions

for a friendly, neutral, or sad Sensoface are summarized in the

following chart. Additional icons refer to the error cause.

Note:

The worsening of a Sensoface criterion leads to the devaluation

of the Sensoface indicator (Smiley becomes “sad”). To reset the

Sensoface indicator, the defect must be remedied and the trans-

mitter be calibrated.