<3. About Fieldbus>

3-1

IM 01C25R03-01E

3. About Fieldbus

3.1 Outline

Fieldbus is a widely used bi-directional digital

communication protocol for field devices that

enable the simultaneous output to many types of

data to the process control system.
The EJX multivariable transmitter Fieldbus

communication type employs the specification

standardized by The Fieldbus Foundation, and

provides interoperability between Yokogawa

devices and those produced by other

manufacturers. Fieldbus comes with software

consisting of five AI function blocks that enable the

flexible implementation of systems.
For information on other features, engineering,

design, construction work, startup and maintenance

of Fieldbus, refer to “Fieldbus Technical Information”

(TI 38K03A01-01E).

3.2 Internal Structure of EJX

Multivariable Transmitter

The EJX Multivariable transmitter contains two

virtual field devices (VFD) that share the following

functions.

3.2.1 System/network Management VFD

• Sets node addresses and Physical Device tags

(PD Tag) necessary for communication.

• Controls the execution of function blocks.

• Manages operation parameters and

communication resources (Virtual

Communication Relationship: VCR).

3.2.2 Function Block VFD

(1) Resource block

• Manages the status of EJX hardware.

• Automatically informs the host of any detected

faults or other problems.

(2) SENSOR Transducer block

• Converts sensor output to pressure, static

pressure, and capsule temperature signals,

and transfers to the AI function blocks and flow

transducer blok.

(3) FLOW Transducer block

• Accepts differential pressure, static pressure

and external temperature data from the

transducer block, calculates flow, and transfer

to the AI function block.

(4) LCD Transducer block

• Controls the display of the integral indicator.

(5) AI function block

• Condition raw data from the Transducer block.

• Output differential pressure, static pressure and

capsule temperature signals.

• Carry out scaling, damping and square root

extraction.

(6) SC function block

• Converts the input signal value based on the

segment table function.

(7) IT function block

• Integrates one or two input signals and outputs

the result.

(8) IS function block

• Selects one of multiple input signals according

to the specified selection method and outputs

the signal.

(9) AR function block

• Performs ten types of calculations on a

combination of two main input signals and three

auxiliary input signals.

(10) PID function block

• Performs the PID control computation based on

the deviation of the measured value from the

setpoint.