Yokogawa EJX930A User Manual

Page 68

Advertising
background image

<9. Parameter Lists>

9-4

IM 01C25R03-01E

Relative

Index Index

Parameter Name

Factory Default

Write

Mode

Explanation

23

2023 SENSOR_CAL_

METHOD

103: factory

trim standard

calibration

O/S

The method of the last sensor calibration.

100=volumetric

101=static weight

102=dynamic weight

103=factory trim standard calibration

104=user trim standard calibration

105=factory trim special calibration

106=user trim special calibration

255=others

24

2024 SENSOR_CAL_LOC

O/S

Set/indicate the location of the last sensor calibration.

25

2025 SENSOR_CAL_DATE —

O/S

Set/indicate the date of the last sensor calibration.

26

2026 SENSOR_CAL_WHO —

O/S

Set/indicate the name of the person responsible for the last

sensor calibration.

27

2027 SENSOR_ISOLATOR_

MTL

Unkown

Defines the construction material of the isolating diaphragms.

28

2028 SENSOR_FILL_FLUID Unkown

Defines the type of fluid used in the sensor.

29

2029 SECONDARY_VALUE

Static pressure (high pressure side) value and status.

30

2030 SECONDARY_

VALUE_UNIT

1545 (MPaa)

The engineering unit of static pressure (high pressure side).

This unit is linked to XD_SCALE.unit of AI blocks.

31

2031 CAL_DEVIATION_HI

0

O/S

Deviation value for span adjustment.

32

2032 CAL_DEVIATION_LO 0

O/S

Deviation value for zero adjustment.

33

2033 EXTERNAL_ZERO_

TRIM

0

O/S

Permission of external zero-adjustment.

34

2034 PRIMARY_VALUE_

FTIME

2

O/S

Damping time constant for primary value.

35

2035 TERTIARY_VALUE

Value and status of static pressure at low side.

36

2036 SP_VALUE_TYPE

109 (absolute

pressure)

O/S

Select the type of measurement for static pressure, absolute or

gauge.

37

2037 SP_VALUE_RANGE

Range of capsule —

High and low range limit values, engineering units, and decimal

point place for static pressure.

38

2038 CAL_SP_POINT_HI

25

O/S

The highest calibrated value for static pressure.

39

2039 CAL_SP_POINT_LO

0

O/S

The Lowest calibrated value for static pressure.

40

2040 CAL_SP_MIN_SPAN

1.0

The minimum calibration span allowed for static pressure.

41

2041 CAL_SP_UNIT

1545 (MPaa)

The calibrated engineering unit for static pressure. This unit is

linked to XD_SCALE.unit of AI blocks.

42

2042 CAL_SP_DEVIATION_

HI

0

O/S

Deviation value for span adjustment of static pressure.

43

2043 CAL_SP_DEVIATION_

LO

0

O/S

Deviation value for zero adjustment of static pressure.

44

2044 SP_VALUE_FTIME

1

O/S

Damping time constant for static pressure.

45

2045 ATM_PRESS

101.325

O/S

Atmosphere pressure value used to obtain gauge pressure

value from absolute pressure.

46

2046 CURRENT_ATM_

PRESS_ENABLE

0

O/S

Automatically sets the L-side static pressure value to the

atmospheric pressure value (ATM_PRESS).

47

2047 EXT_TEMP_VAL

Indicates the external temperature value and status.

48

2048 EXT_TEMP_RANGE

-200 to 850°C

Indicates the external temperature sensor range, unit and

decimal point.

49

2049 CAL_EXT_TEMP_

POINT_HI

100

O/S

This is High-side adjustment value. Adjust this value so that the

current external temperature becomes this setting value.

50

2050 CAL_EXT_TEMP_

POINT_LO

0

O/S

This is Low-side adjustment value. Adjust this value so that the

current external temperature becomes this setting value.

51

2051 CAL_EXT_TEMP_

MIN_SPAN

10.0

Indicates the minimum span of the external temperature.

52

2052 CAL_EXT_TEMP_

UNIT

1001

Indicates the calibration unit of the external temperature sensor.

53

2053 CAL_EXT_TEMP_

DEVIATION_HI

0

O/S

This is the adjustment coefficient for performing span

adjustment of the external temperature.

54

2054 CAL_EXT_TEMP_

DEVIATION_LO

0

O/S

This is the adjustment coefficient for performing zero adjustment

of the external temperature.

55

2055 EXT_TEMP_VALUE_

FTIME

1.0

O/S

Sets the primary filter time constant (unit: seconds) of the

external temperature.

56

2056 EXT_TEMP_OPTS

0

O/S

Selects the external temperature selection operation.

0=No Selection OFF (output of external temperature)

1=Yes Selection ON (output of FIXED_EXT_TEMP_VALUE)

2=Fall Back Selection at broken wire (output of FIXED_EXT_

TEMP_VALUE at broken wire)