<9. Parameter Lists>

9-7

IM 01C25R03-01E

Relative

Index Index

Parameter Name

Factory Default

Write

Mode

Explanation

9

2309 TRANSDUCER_

DIRECTORY

This parameter is for storing the index of the transducer to be

included in the transmitter.

10

2310 TRANSDUCER_TYPE 104 (Standard

Flow with

Calibration)

Indicates the type of transmitter.

11

2311 XD_ERROR

Stores the most important error among the errors currently

occurring in the transducer block.

When “0” is stored, this means that no errors are occurring.

12

2312 COLLECTION_

DIRECTORY

Stores the index of important parameters in the transducer

block and the item ID of the corresponding DD.

13

2313 FLOW_VALUE_TYPE 1

Indicates the type of flow.

1: Mass flow

2: Volume flow

3: Standard volume flow

14

2314 FLOW_VALUE

Indicates the flow value and its status.

15

2315 FLOW_VALUE_UNIT 1324: kg/h

Indicates the unit of the flow value.

16

2316 FLOW_VALUE_

DECIMAL

0

Indicates the number of digits past the decimal point of the flow

value.

17

2317 FLOW_VALUE_FTIME 0

O/S

Indicates the primary filter time constant (unit: seconds) of the

flow value.

18

2318 DIFF_PRESSURE

Indicates the differential pressure value used in the flow

calculation and its status.

19

2319 DIFF_PRESSURE_

UNIT

1133 (kPa)

O/S

Sets the unit of the differential pressure value.

20

2320 STATIC_PRESSURE

Indicates the static pressure value used in the flow calculation

and its status.

21

2321 STATIC_PRESSURE_

UNIT

1545 (MPaa)

O/S

Sets the unit of the static pressure value.

22

2322 EXT_TEMPERATURE —

Indicates the external temperature value used in the flow

calculation and its status.

23

2323 EXT_TEMPERAURE_

UNIT

1001 (°C)

O/S

Sets the unit of the external temperature value.

24

2324 FLOW_

CALCULATION_MODE

0

O/S

Switches the flow calculation mode.

0: Auto Compensation Mode

1: Basic Mode

25

2325 FIXED_FLOW_VALUE 0

O/S

Sets the flow calculation coefficient (Kfactor) used in the Basic

Mode.

26

2326 REF_STATIC_

PRESSURE

0.101325

O/S

Sets the design reference static pressure value used in the

Basic Mode.

27

2327 REF_EXT_

TEMPERATURE

0

O/S

Sets the design reference temperature value used in the Basic

Mode.

28

2328 TEMP_K1_FOR_

LIQUID

0

O/S

Sets the temperature coefficient for density compensation used

when calculating the liquid flow in the Basic Mode.

29

2329 FLUID_TYPE_CODE 2

O/S

Sets the fluid code in the Basic Mode.

1: Liquid

2: Gas

30

2330 ALARM_SUM

Alarm / Enable

Indicates the alarm state of the entire block.

31

2331 DENSITY_UNIT_

CODE

*1

1097 (kg/m

3

)

O/S

Indicates the density unit.

1097: kg/m

3

1107: lb/ft3

32

2332 LENGTH_UNIT_

CODE

*1

1010 (m)

O/S

Indicates the length unit.

1018: ft

1010: m

1019: in

1012: cm

1013: mm

33

2333 PRIMARY_DEVICE_

CODE

*1

2

O/S

Indicates the diaphragm type code.

For details on type code, see Table 9.1.

34

2334 PRIMARY_DEVICE_

DIAMETER

*1

0.03162

O/S

Indicates the diaphragm inner diameter.

35

2335 PRIMARY_DEVICE_

EXPANSION_COEF

*1

0.00001681

O/S

Indicates the diaphragm linear expansion coefficient value.

36

2336 PRIMARY_

DEVICE_REF_

TEMPERATURE

*1

20

O/S

Indicates the temperature during diaphragm inner diameter

measurement.

37

2337 PIPE_DIAMETER

*1

0.0527

O/S

Indicates the pipe inner diameter.