<9. Parameter Lists>

9-1

IM 01C25R03-01E

9. Parameter Lists

Note: The Write Mode column contains the modes in which each parameter is write enabled.

O/S: Write enabled in O/S mode.

MAN: Write enabled in Man mode and O/S mode.

AUTO: Write enabled in Auto mode, Man mode, and O/S mode.

9.1 Resource Block

Relative

Index Index

Parameter Name

Factory Default

Write

Mode

Explanation

0

1000 Block Header

TAG:“RS”

Block

Tag=O/S

Information on this block such as Block Tag, DD Revision,

Execution Time etc.

1

1001 ST_REV

The revision level of the static data associated with the resource

block. The revision value is incremented each time a static

parameter value in this block is changed.

2

1002 TAG_DESC

Null

AUTO

The user description of the intended application of the block.

3

1003 STRATEGY

1

AUTO

The strategy field can be used to identify grouping of blocks.

This data is not checked or processed by the block.

4

1004 ALERT_KEY

1

AUTO

The identification number of the plant unit. This information may

be used in the host for sorting alarms, etc.

5

1005 MODE_BLK

AUTO

AUTO

The actual, target, permitted, and normal modes of the block.

6

1006 BLOCK_ERR

This parameter reflects the error status associated with the

hardware or software components associated with a block. It is

a bit string, so that multiple errors may be shown.

7

1007 RS_STATE

State of the resource block state machine.

8

1008 TEST_RW

Null

AUTO

Read/write test parameter-used only for conformance testing

and simulation.

9

1009 DD_RESOURCE

Null

String identifying the tag of the resource which contains the

Device Description for this resource.

10

1010 MANUFAC_ID

0x00594543

Manufacturer identification number-used by an interface device

to locate the DD file for the resource.

11

1011 DEV_TYPE

14 (0x000E)

Manufacturer’s model number associated with the resource-

used by interface devices to locate the DD file for the resource.

12

1012 DEV_REV

2

Manufacturer revision number associated with the resource-

used by an interface device to locate the DD file for the

resource.

13

1013 DD_REV

1

Revision of the DD associated with the resource-used by an

interface device to locate the DD file for the resource.

14

1014 GRANT_DENY

0

AUTO

Options for controlling access of host computer and local control

panels to operating, tuning and alarm parameters of the block.

15

1015 HARD_TYPES

Scalar input

The types of hardware available as channel numbers.

bit0: Scalar input

bit1: Scalar output

bit2: Discrete input

bit3: Discrete output

16

1016 RESTART

Allows a manual restart to be initiated. Several degrees of

restart are possible. They are 1: Run, 2: Restart resource, 3:

Restart with initial value specified in FF functional spec. (*1),

and 4: Restart processor.

*1: FF-891 Foundation

TM

Specification Function Block

Application Process Part 2.

17

1017 FEATURES

Soft write lock

supported Report

supported

Used to show supported resource block options.

18

1018 FEATURE_SEL

Soft write lock

supported Report

supported

AUTO

Used to select resource block options defined in FEATURES.

bit0: Scheduled

bit1: Event driven

bit2: Manufacturer specified

19

1019 CYCLE_TYPE

Scheduled

Identifies the block execution methods available for this

resource.

20

1020 CYCLE_SEL

Scheduled

AUTO

Used to select the block execution method for this resource.

21

1021 MIN_CYCLE_T

3200 (100ms)

Time duration of the shortest cycle interval of which the

resource is capable.

Advertising